Skip to main navigation Skip to search Skip to main content

A Novel Vision Transformer + InceptionV3 Hybrid Network for Accurate Diagnosis of Ankylosing Spondylitis from Computed Tomography Scans

  • Riel Castro-Zunti
  • , Eun Hae Park
  • , Amol Satsangi
  • , Younhee Choi
  • , Gong Yong Jin
  • , Hee Suk Chae
  • , Seok Bum Ko
  • University of Saskatchewan
  • Dayalbagh Educational Institute India
  • Jeonbuk National University

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Rationale and objectives: Ankylosing spondylitis (AS) is a lifelong form of arthritis that inflames the sacroiliac joints (SIJs) and spine. Compared to magnetic resonance imaging (MRI), computed tomography (CT) better images bony erosions within SIJs - subtle early-stage AS indicators - and CT is considered the “gold standard” AS diagnostic modality. While clinical AS diagnoses via CT yield impressive specificity, sensitivity often lags. Materials and methods: Using 2 000+ SIJs across the pelvic CT scans of 35 AS patients and 65 control patients, a 3-stage computer vision diagnostic pipeline was developed: SIJ localization/extraction using YOLOv5; classifying SIJs as AS (across various progression levels) or control (across young and old age groups) via a custom vision transformer (ViT) + InceptionV3 hybrid architecture; and using aggregated/normalized SIJ classification results to predict AS at the patient level using a traditional machine learning model. Results: For 73 patients with > 8 SIJs (restriction limits the impact of SIJ misclassifications), the proposed pipeline achieved 98.63% accuracy, 96.43% sensitivity, perfect specificity, and 96.51% ROC AUC. It is demonstrated to be robust and outperforms retrained related works. Compared to vanilla ViT for SIJ classification, the hybrid model pipeline is 16% more accurate with 14% higher ROC AUC; compared to vanilla InceptionV3, it is 7% more accurate with 4% higher ROC AUC. Conclusion: AS can be diagnosed with high sensitivity and specificity via the proposed pipeline. ViT + InceptionV3 outperforms its baseline forebears while unifying their respective strengths. Being able to capture global and local details, ViT + InceptionV3 is applicable to tasks within computer assisted diagnostics and elsewhere.

Original languageEnglish
Pages (from-to)1061-1087
Number of pages27
JournalMachine Intelligence Research
Volume22
Issue number6
DOIs
StatePublished - Dec 2025

Keywords

  • Vision transformers
  • ankylosing spondylitis
  • classification
  • computed tomography
  • computer assisted diagnostics
  • deep learning

Fingerprint

Dive into the research topics of 'A Novel Vision Transformer + InceptionV3 Hybrid Network for Accurate Diagnosis of Ankylosing Spondylitis from Computed Tomography Scans'. Together they form a unique fingerprint.

Cite this