Artifact reduction in truncated CT using Sinogram completion

  • SUNY Buffalo
  • Erie County Medical Center

Research output: Contribution to journalConference articlepeer-review

30 Scopus citations

Abstract

Truncation of projection data in CT produces significant artifacts in the reconstruction process due to non-locality of the Radon transform. In this paper, we present a method for reducing these truncation artifacts by estimating features that lie outside the region of interest (ROI) and using these features to complete the truncated sinogram. Projection images of an object are obtained. A sinogram is obtained by stacking profile data from all projection angles. A simulated truncated sinogram is generated by setting pixel values outside an ROI to zero. The truncated sinogram is then transformed into a (radius, phase) image, with pixel values in what we term as the Polar representation (PR) image corresponding to the minimum value along sine curves given by x = r*cos(projection angle + phase). The PR image contains data for radii greater than the ROI radius. Pixel values outside the ROI in the completed sinogram are determined as follows. For each pixel in the PR image, a sine curve is generated in the completed sinogram image outside the ROI, having the same pixel value as that of the PR image for that radius and phase. Successive sine curves are laid and the values of each are summed. The intensity outside is then equalized to the intensity inside the ROI. The completed sinogram is then reconstructed, to obtain completed reconstruction. The percentage error in the difference image between the full FOV reconstruction and the corresponding completed reconstruction and the extrapolated-average reconstruction are 1.1% and 3.3% respectively. This indicates that the completed reconstruction is closer to full FOV reconstruction. Thus, the sinogram completion can be used to improve reconstructions from truncated data.

Original languageEnglish
Article number247
Pages (from-to)2110-2117
Number of pages8
JournalProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume5747
Issue numberIII
DOIs
StatePublished - 2005
EventMedical Imaging 2005 - Image Processing - San Diego, CA, United States
Duration: Feb 13 2005Feb 17 2005

Keywords

  • Artifact reduction
  • Dose reduction
  • Extrapolation
  • Reduced FOV
  • Sinogram
  • Sinogram completion
  • Truncated reconstruction

Fingerprint

Dive into the research topics of 'Artifact reduction in truncated CT using Sinogram completion'. Together they form a unique fingerprint.

Cite this