Skip to main navigation Skip to search Skip to main content

Congruence between the meshes of a combined healing abutment-scan body system acquired with four different intraoral scanners and the corresponding library file: An in vitro analysis

Research output: Contribution to journalArticlepeer-review

24 Scopus citations

Abstract

Objectives: To investigate the congruence between the meshes of a combined healing abutment-scan body (CHA-SB) system acquired with four different intraoral scanners and the corresponding library file. Material and methods: A CHA-SB was fixed to an implant at the right first molar position in a dentate mandibular model and digitized by using 4 different intraoral scanners (IOSs) [TRIOS 3 (T3), Omnicam (OC), Primescan (PS), and Virtuo Vivo (VV)] (n = 8) and an industrial grade optical scanner (ATOS Core 80) (n = 1) to generate standard tessellation language (STL) files of the test scans (CHA-SB-STLs) and the master reference model scan (MRM-STL). A reverse engineering software (Studio Geomagic X) was used to superimpose the proprietary library file of the CHA-SB over the generated STL files. Root mean square (RMS) values representing the deviations between the library file and the superimposed STL files were statistically analyzed by using 1-way ANOVA (α=0.05). Qualitative analysis of the deviations was performed by visual inspection. Results: Differences between the congruence of the library file and the CHA-SB scans among different IOSs were nonsignificant (F = 1.619, df= 3, P = .207). The single best result was 29 ± 28.9 µm for OC, 30.8 ± 29.6 µm for VV, 35.6 ± 35.5 µm for T3, and 39.5 ± 39.2 µm for PS, which were all above the deviation value of the scan performed by using the industrial-grade scanner (23.2 ± 23.2 µm). Conclusion: The dimensional congruence between the library file and the STL file of the CHA-SB system scans was similar when intraoral scanners with different acquisition technologies were used to scan a model with an implant. Clinical significance: Scans of the tested intraoral scanners may result in crowns with similar positional accuracy, given the similarities in congruence of their scans with the library file.

Original languageEnglish
Article number103938
JournalJournal of Dentistry
Volume118
DOIs
StatePublished - Mar 2022

Keywords

  • Accuracy
  • Healing abutment-scan body
  • Intraoral scanner
  • Trueness

Fingerprint

Dive into the research topics of 'Congruence between the meshes of a combined healing abutment-scan body system acquired with four different intraoral scanners and the corresponding library file: An in vitro analysis'. Together they form a unique fingerprint.

Cite this