Abstract
We describe a new quantitative electrochemical technique for measuring the copper redistribution that occurs during corrosion and pretreatment of high-strength copper-containing aluminum alloys. Underpotential deposition (upd) of Pb on Cu was used to assay the surface coverage of Cu. Model experiments using samples of known Al-Cu ratios were used to evaluate the accuracy of the technique and develop a calibration curve. The results demonstrated the accuracy of the method to within 2%. The elemental copper remaining on the surface of Al 2024-T3 samples after various pretreatment/corrosion procedures was determined using the upd technique. A simple treatment involving open-circuit etching of the alloy surface in 3 M HNO3 was found to be most efficient for the removal of Cu from the Al alloy surface. In accord with a recent observation of Bucheit et al.,1 convection was found to enhance copper redistribution on an Al 2024-T3 sample in 0.5 M NaCl solution.
| Original language | English |
|---|---|
| Pages (from-to) | 98-102 |
| Number of pages | 5 |
| Journal | Journal of the Electrochemical Society |
| Volume | 146 |
| Issue number | 1 |
| DOIs | |
| State | Published - 1999 |
Fingerprint
Dive into the research topics of 'Copper redistribution during corrosion of aluminum alloys'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver