TY - GEN
T1 - Development and assessment of statistical iterative image reconstruction for CT on a small animal SPECT/CT dual-modality system
AU - Dai, Tiantian
AU - Deng, Xiao
AU - Ionita, Ciprian N.
AU - Wei, Qingyang
AU - Ma, Tianyu
AU - Liu, Yaqiang
AU - Bednarek, Daniel R.
AU - Rudin, Stephen
AU - Yao, Rutao
PY - 2012
Y1 - 2012
N2 - We developed a statistical iterative CT image reconstruction software for a newly constructed high-resolution small animal SPECT/CT dual-modality system, and assessed its performance at different radiation exposure levels. The objective of this work was to preserve or improve reconstructed image quality at either the same or reduced animal x-ray radiation exposure. The SPECT/CT system used a single detector for both the CT and SPECT modalities that consists of a micro-columnar CsI(Tl) phosphor, a light image intensifier (LII) and a CCD sensor. The CT reconstruction software was based on the ordered-subset-convex (OSC) algorithm, and the system matrix was calculated through a ray-driven approach. A self-calibration method was implemented to calculate the offset of the axis of rotation (AOR), an important geometry parameter of the system. An endovascular stent was imaged to evaluate the high resolution performance of the statistical reconstructed image. A sacrificed mouse was scanned at different exposure levels to assess the effect of statistical noise on the image. The mouse studies were reconstructed with both the statistical reconstruction software and a filtered back-projection (FBP) program. The images were assessed and compared by contrast to noise ratio (CNR) in the region of interest. The images yielded by the statistical reconstruction software were artifact free and show superior noise performance to those from FBP reconstruction at different radiation exposure levels. The statistical reconstructed images with reduced exposure showed obviously higher image quality than those from FBP reconstruction at full exposure.
AB - We developed a statistical iterative CT image reconstruction software for a newly constructed high-resolution small animal SPECT/CT dual-modality system, and assessed its performance at different radiation exposure levels. The objective of this work was to preserve or improve reconstructed image quality at either the same or reduced animal x-ray radiation exposure. The SPECT/CT system used a single detector for both the CT and SPECT modalities that consists of a micro-columnar CsI(Tl) phosphor, a light image intensifier (LII) and a CCD sensor. The CT reconstruction software was based on the ordered-subset-convex (OSC) algorithm, and the system matrix was calculated through a ray-driven approach. A self-calibration method was implemented to calculate the offset of the axis of rotation (AOR), an important geometry parameter of the system. An endovascular stent was imaged to evaluate the high resolution performance of the statistical reconstructed image. A sacrificed mouse was scanned at different exposure levels to assess the effect of statistical noise on the image. The mouse studies were reconstructed with both the statistical reconstruction software and a filtered back-projection (FBP) program. The images were assessed and compared by contrast to noise ratio (CNR) in the region of interest. The images yielded by the statistical reconstruction software were artifact free and show superior noise performance to those from FBP reconstruction at different radiation exposure levels. The statistical reconstructed images with reduced exposure showed obviously higher image quality than those from FBP reconstruction at full exposure.
UR - https://www.scopus.com/pages/publications/84881600819
U2 - 10.1109/NSSMIC.2012.6551776
DO - 10.1109/NSSMIC.2012.6551776
M3 - Conference contribution
SN - 9781467320306
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 3409
EP - 3411
BT - 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2012
T2 - 2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record, NSS/MIC 2012
Y2 - 29 October 2012 through 3 November 2012