TY - GEN
T1 - Evaluation of thermal performance factor of novel two-pass, ribbed, u-shaped channel for solar air heater
AU - Salameh, Tareq
AU - Siddiuue, Waseem
AU - Raheem, Aneeq
AU - Al Alami, Abdul Hai
N1 - Publisher Copyright: © 2020 IEEE.
PY - 2020/2
Y1 - 2020/2
N2 - Solar is a clean, convenient, sustainable, safe, abundant and economical source of energy. Solar Air Heater (SAH) is widely used in solar energy applications. In the current study, an attempt is made to increase the efficiency of SAH. A novel ribbed double pass U-shaped channel with a sharp turn is used as the channel of absorbing plate. Two ribs are implemented on the inlet and middle of the turn part of two-pass channel. The study of thermo-hydraulic performance inside the sharp part for two ribs at the inlet and middle of the outer wall are studied at pitch ratio and the rib height-to-hydraulic diameter ratio (e/Dh) of 13.5 and 0.1 respectivelly and Reynolds number of 20, 000. All the cases are compared based on a smooth channel. It is observed that friction factor decreases by 42%, Nusselt number increases by 1.96% and thermo-hydraulic performance index increases by 20% as compared to the smooth channel.
AB - Solar is a clean, convenient, sustainable, safe, abundant and economical source of energy. Solar Air Heater (SAH) is widely used in solar energy applications. In the current study, an attempt is made to increase the efficiency of SAH. A novel ribbed double pass U-shaped channel with a sharp turn is used as the channel of absorbing plate. Two ribs are implemented on the inlet and middle of the turn part of two-pass channel. The study of thermo-hydraulic performance inside the sharp part for two ribs at the inlet and middle of the outer wall are studied at pitch ratio and the rib height-to-hydraulic diameter ratio (e/Dh) of 13.5 and 0.1 respectivelly and Reynolds number of 20, 000. All the cases are compared based on a smooth channel. It is observed that friction factor decreases by 42%, Nusselt number increases by 1.96% and thermo-hydraulic performance index increases by 20% as compared to the smooth channel.
KW - Friction factor
KW - Nusselt number
KW - Pitch ratio
KW - Rib height-to-hydraulic diameter ratio
KW - Ribs
KW - Solar Air Heater
KW - Thermal performance factor
UR - https://www.scopus.com/pages/publications/85087460841
U2 - 10.1109/ASET48392.2020.9118194
DO - 10.1109/ASET48392.2020.9118194
M3 - Conference contribution
T3 - 2020 Advances in Science and Engineering Technology International Conferences, ASET 2020
BT - 2020 Advances in Science and Engineering Technology International Conferences, ASET 2020
PB - Institute of Electrical and Electronics Engineers Inc.
T2 - 2020 Advances in Science and Engineering Technology International Conferences, ASET 2020
Y2 - 4 February 2020 through 9 April 2020
ER -