Skip to main navigation Skip to search Skip to main content

Experimental measurements of temperature distribution in three dimensional stacked package

  • State University of New York Binghamton University

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

This paper presents the results of an experimental study of steady state heat conduction in a three dimensional stack package. The temperatures are measured at different interfaces within the stacked package. Delphi devices are used in the experiment which enables controlled power input and surface temperature of the devices. The experiment is carried out for three different boundary conditions on the package. The power input in varied to study its effects. A numerical model is created to compare to the experimental results. The results are also compared with the analytical solution presented in Desai et al [5] and Geer et al [6]. The results indicate that the experimental, numerical and analytical solutions follow the same trend. The agreement between the experimental and numerical results improves when the lateral losses are taken into account.

Original languageEnglish
Title of host publication2007 Proceedings of the ASME InterPack Conference, IPACK 2007
Pages617-623
Number of pages7
DOIs
StatePublished - 2007
EventASME Electronic and Photonics Packaging Division - Vancouver, BC, United States
Duration: Jul 8 2007Jul 12 2007

Publication series

Name2007 Proceedings of the ASME InterPack Conference, IPACK 2007
Volume2

Conference

ConferenceASME Electronic and Photonics Packaging Division
Country/TerritoryUnited States
CityVancouver, BC
Period07/8/0707/12/07

Fingerprint

Dive into the research topics of 'Experimental measurements of temperature distribution in three dimensional stacked package'. Together they form a unique fingerprint.

Cite this