Abstract
The fatigue-life of low carbon steel was found to be significantly enhanced following implantation of 150 kev N//2** plus . The observed lifetimes were found to be dependent on the thermal history of the samples.
| Original language | English |
|---|---|
| Pages (from-to) | 71-72 |
| Number of pages | 2 |
| Journal | Radiation effects |
| Volume | 49 |
| Issue number | 1-3 |
| DOIs | |
| State | Published - 1980 |
| Event | Proc of the Int Conf on Ion Beam Modif of Mater - Budapest, Hung Duration: Sep 4 1978 → Sep 8 1978 |
Fingerprint
Dive into the research topics of 'FATIGUE-LIFE ENHANCEMENT OF STEEL BY NITROGEN IMPLANTATION.'. Together they form a unique fingerprint.Cite this