First United States multicenter experience with the new-generation FRED X surface-modified flow diversion stent: feasibility, safety, and short-term efficacy

  • Rawad Abbas
  • , Matthews Lan
  • , Kareem El Naamani
  • , Elias Atallah
  • , Mohamed Salem
  • , Jan Karl Burkhardt
  • , Anna Luisa Kühn
  • , Ajit Puri
  • , Andre Monteiro
  • , Elad I. Levy
  • , Nabeel A. Herial
  • , M. Reid Gooch
  • , Jeffrey Jabbour
  • , Robert Rosenwasser
  • , Stavropoula I. Tjoumakaris
  • Thomas Jefferson University
  • University of Pennsylvania
  • University of Massachusetts Boston
  • SUNY Buffalo
  • Germantown Friends School

Research output: Contribution to journalArticlepeer-review

17 Scopus citations

Abstract

OBJECTIVE Flow diversion created a paradigm shift in the treatment of intracranial aneurysms. The new flow redirection endoluminal device with X technology (FRED X) is the latest update of the recent Food and Drug Administration-approved FRED. The FRED X is engineered to reduce material thrombogenicity and enhance vessel healing. In this study, the authors aimed to evaluate the feasibility and early safety and efficacy of the new FRED X. METHODS The authors retrospectively collected and analyzed data from patients who had undergone flow diversion with the new FRED X at four tertiary cerebrovascular centers in the United States from February 2022 through July 2022. RESULTS Forty-four patients with 45 aneurysms treated using 46 devices comprised the overall study cohort and were divided into two groups: 39 patients with unruptured aneurysms and 5 patients with ruptured aneurysms. The mean patient age was 57.7 ± 9.1 years, and most patients were female (84%). Ninety-one percent of the aneurysms were saccular, with the majority (93%) located in the anterior circulation, specifically the posterior communicating (27%) and carotid ophthalmic (27%) territories. The mean maximum aneurysm diameter was 5.6 ± 4.6 mm, and 20% of the lesions had been previously treated. The mean procedure time was 61.6 minutes, with a mean cumulative fluoroscopy time of 24.6 minutes. Additionally, 7% of the lesions received adjunct treatment. Stent placement was successful in 100% of cases, achieving good wall apposition and complete neck coverage. Further, immediate aneurysm contrast stasis > 90% was observed in 61% of cases. Symptomatic postoperative complications occurred in 3 patients in the unruptured cohort and 1 patient in the ruptured cohort. All patients in the study were discharged on dual antiplatelet regimens with a modified Rankin Scale score of 0. At 6 months after treatment, 89% of cases had adequate occlusion, with < 6% of cases having asymptomatic in-stent stenosis. All patients had excellent functional outcomes. CONCLUSIONS FRED X for the treatment of an intracranial aneurysm is technically feasible alone or in conjunction with intrasaccular embolization. In addition, the study results showed very promising early safety and efficacy. Follow-up studies should establish the long-term safety and efficacy profiles of this new stent.

Original languageEnglish
Pages (from-to)1054-1063
Number of pages10
JournalJournal of Neurosurgery
Volume140
Issue number4
DOIs
StatePublished - 2024

Keywords

  • FRED X
  • aneurysm
  • angiography
  • endovascular neurosurgery
  • flow diversion
  • flow diverter stent
  • surface modification
  • vascular disorders