Skip to main navigation Skip to search Skip to main content

Image quality and radiation dose of ultra-low current CT colonography with adaptive iterative dose reduction three-dimensional in pig model

  • He Song Shen
  • , Dan Liang
  • , Ming Yue Luo
  • , Chai Jie Duan
  • , Cai Wen-Li
  • , Shan Shan Zhu
  • , Jian Ping Qiu
  • , Wen Ru Li
  • , Jerome Z. Liang
  • Sixth Affiliated Hospital of Sun Yat-Sen University
  • Tsinghua University
  • Massachusetts General Hospital

Research output: Contribution to journalArticlepeer-review

Abstract

Objective: To investigate image quality and radiation dose of ultra-low current CT colonography with adaptive iterative dose reduction three-dimensional (AIDR3D) in pig model. Methods: Ten segments of porcine colon models were established, of which thirty pedunculated polyps with diameters ranging from 1 mm to 15 mm were implanted. All colon models were scanned using 640-slice CT scanner with tube voltage of 120 kVp, and current of 10, 20, 30, 40, 50 mAs, respectively. CT colonography images were reconstructed using filtered back projection (FBP) and AIDR3D. Ten groups data were obtained with 5 current doses and 2 reconstruction algorithms: Group A (10 mAs, FBP), group B (10 mAs, AIDR3D), group C (20 mAs, FBP), group D (20 mAs, AIDR3D), group E (30 mAs, FBP), group F (30 mAs, AIDR3D), group G (40 mAs, FBP), group H (40 mAs, AIDR3D), group I (50 mAs, FBP), group J (50 mAs, AIDR3D). Quantitative image quality evaluation was preformed, included image noise, SNR, and contrast-to-noise ratio (CNR). Qualitative image quality was also evaluated. Radiation dose was compared with the index of effective radiation dose. Results: At the same level of current, image noise with AIDR3D was lower than that with FBP, while SNR and CNR with AIDR3D were higher than those with FBP (all P<0.05). There was no statistically significant difference in image noise (P=0.052), SNR (P=0.129) and CNR (P=0.053) between groups D and I. Image noise of group B was higher than that of group I (P=0.002), while SNR and CNR were all lower than group I (both P<0.001). Qualitative image quality scores with AIDR3D were higher than that with FBP at the same level of current doses (all P<0.05). No significant difference of qualitative image quality scores between groups D and I was found (P=0.121). Qualitative image quality score of group B was lower than that of group I (P<0.001). Compared with group I, effective radiation dose of group D decreased by 59.90% (P<0.05). Conclusion: Image quality of ultra-low current of 20 mAs CT colonography with AIDR3D is comparable to currently standard low current dose of 50 mAs with FBP, and can decrease radiation dose effectively.

Original languageEnglish
Pages (from-to)122-126
Number of pages5
JournalChinese Journal of Medical Imaging Technology
Volume31
Issue number1
DOIs
StatePublished - Jan 20 2015

Keywords

  • Adaptive iterative dose reduction three-dimensional
  • Colonography, computed tomographic
  • Current
  • Image quality
  • Radiation dose

Fingerprint

Dive into the research topics of 'Image quality and radiation dose of ultra-low current CT colonography with adaptive iterative dose reduction three-dimensional in pig model'. Together they form a unique fingerprint.

Cite this