TY - GEN
T1 - Initial study of the radiomics of intracranial aneurysms using Angiographic Parametric Imaging (API) to evaluate contrast flow changes
AU - Chandra, Anusha Ramesh
AU - Podgorsak, Alexander R.
AU - Waqas, Mohammad
AU - Shiraz Bhurwani, Mohammad Mahdi
AU - Shallwani, Hussain
AU - Marshall, Jordan
AU - Siddiqui, Adnan H.
AU - Davies, Jason M.
AU - Rudin, Stephen
AU - Ionita, Ciprian N.
N1 - Publisher Copyright: © SPIE. Downloading of the abstract is permitted for personal use only.
PY - 2019
Y1 - 2019
N2 - The purpose of this study is to apply targeted Parametric Imaging on aneurysms to quantitatively investigate contrast flow changes at pre-, post-treatment and follow-up with outcome scoring. Methods: The angiograms for 50 patients were acquired, 25 treated with coil embolization and 25 treated using a flow diverter. API was performed by synthesizing the time density curve (TDC) at every pixel. Based on the TDCs, we calculated various parameters for the quantitative characterization of contrast flow through the vascular network and aneurysms and displayed them using color encoded maps. The parameters included were: Time to Peak (TTP), Mean Transit Time (MTT), Time of Arrival (TTA), Peak Height (PH) and Area Under the Curve (AUC). Two Regions of Interest (ROI) were manually marked over the aneurysm dome and the main artery. Average aneurysm parameter values were normalized to those values recorded in the main artery and recorded pre-/post-treatment and follow-up and compared to Raymond Roy scores and flow diverter stent scoring. Results: The normalized mean values were as follows (pre and post treatment): TTP (1.09+/-0.14, 1.55+/-1.36), MTT (1.07+/-0.23, 1.27+/-0.42), TTA (0.14+/-0.15, 0.26+/-0.23), PH (1.2+/-0.54, 0.95+/-0.83) and AUC (1.29+/-0.69, 1.44+/- 1.92). The neural network gave a validation accuracy of 0.8036 with a loss of 0.0927. A receiver operating characteristic curve with an AUC of 0.866 was obtained. Conclusions: API can quantitatively describe the flow in the aneurysm for initial investigation of the radiomics of intracranial aneurysms. It also shows a clear demarcation between pre and post treatment. Statistical modelling and a machine learning network is used to prove the success of our model.
AB - The purpose of this study is to apply targeted Parametric Imaging on aneurysms to quantitatively investigate contrast flow changes at pre-, post-treatment and follow-up with outcome scoring. Methods: The angiograms for 50 patients were acquired, 25 treated with coil embolization and 25 treated using a flow diverter. API was performed by synthesizing the time density curve (TDC) at every pixel. Based on the TDCs, we calculated various parameters for the quantitative characterization of contrast flow through the vascular network and aneurysms and displayed them using color encoded maps. The parameters included were: Time to Peak (TTP), Mean Transit Time (MTT), Time of Arrival (TTA), Peak Height (PH) and Area Under the Curve (AUC). Two Regions of Interest (ROI) were manually marked over the aneurysm dome and the main artery. Average aneurysm parameter values were normalized to those values recorded in the main artery and recorded pre-/post-treatment and follow-up and compared to Raymond Roy scores and flow diverter stent scoring. Results: The normalized mean values were as follows (pre and post treatment): TTP (1.09+/-0.14, 1.55+/-1.36), MTT (1.07+/-0.23, 1.27+/-0.42), TTA (0.14+/-0.15, 0.26+/-0.23), PH (1.2+/-0.54, 0.95+/-0.83) and AUC (1.29+/-0.69, 1.44+/- 1.92). The neural network gave a validation accuracy of 0.8036 with a loss of 0.0927. A receiver operating characteristic curve with an AUC of 0.866 was obtained. Conclusions: API can quantitatively describe the flow in the aneurysm for initial investigation of the radiomics of intracranial aneurysms. It also shows a clear demarcation between pre and post treatment. Statistical modelling and a machine learning network is used to prove the success of our model.
KW - Angiographic parametric imaging
KW - Contrast flow dynamics
KW - Intracranial aneurysm
KW - Neurovascular intervention
KW - Time density curves
UR - https://www.scopus.com/pages/publications/85068373278
U2 - 10.1117/12.2512457
DO - 10.1117/12.2512457
M3 - Conference contribution
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2019
A2 - Schmidt, Taly Gilat
A2 - Chen, Guang-Hong
A2 - Bosmans, Hilde
PB - SPIE
T2 - Medical Imaging 2019: Physics of Medical Imaging
Y2 - 17 February 2019 through 20 February 2019