Is intra-procedure three-dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?

  • Abdul Moiz Hafiz
  • , Giorgio A. Medranda
  • , Nikolaos Kakouros
  • , Jay Patel
  • , Jonathan Kahan
  • , George Gubernikoff
  • , Beevash Ray
  • , Vijayapraveena Paruchuri
  • , Joshua DeLeon
  • , Kevin Marzo
  • , Rose Calixte
  • , Juan Gaztanaga
  • University of Massachusetts Medical School
  • Winthrop University Hospital
  • University of Illinois at Chicago

Research output: Contribution to journalArticlepeer-review

10 Scopus citations

Abstract

Background: The role of three-dimensional transesophageal echocardiography (3DTEE) vs multidetector computed tomography (MDCT) in aortic annular sizing has been poorly defined in patients undergoing transcatheter aortic valve replacements (TAVR). We set to determine the correlation between 3DTEE and MDCT in measuring the aortic annulus prior to TAVR. Methods: In an observational, retrospective study, we compared aortic annular areas measured by MDCT and 3DTEE in TAVR patients. The aortic annular area was measured by planimetry of images obtained by MDCT pre-TAVR and by intra-TAVR TEE using 3D rendering of the aortic annulus followed by planimetry. Our primary outcome was degree of correlation between mean aortic annulus area by 3DTEE and MDCT. Results: Of the 111 consecutive patients undergoing TAVR who had measurements from both modalities available for comparison between February 2012 and April 2015, 87 met inclusion criteria. The mean aortic annular area by MDCT was 4.44±0.88 cm2 and by 3DTEE was 4.33±0.78 cm2. There was a strong positive linear correlation between aortic annular area measurements obtained from these two modalities with mild relative underestimation by 3DTEE (ρ=.833). This relationship can be estimated using the predictive formula:. Conclusions: Three-dimensional transesophageal echocardiography measurements have a high degree of correlation with MDCT measurements and thus can assist in proper valve prosthesis selection for TAVR. Our study thus supports use of 3DTEE as a reasonable alternative imaging modality in patients undergoing TAVR.

Original languageEnglish
Pages (from-to)1195-1202
Number of pages8
JournalEchocardiography
Volume34
Issue number8
DOIs
StatePublished - Aug 2017

Keywords

  • multidetector computed tomography
  • three-dimensional transesophageal echocardiography
  • transcatheter aortic valve replacement

Fingerprint

Dive into the research topics of 'Is intra-procedure three-dimensional transesophageal echocardiogram an alternative to preprocedure multidetector computed tomography for the measurement of the aortic annulus in patients undergoing transcatheter aortic valve replacement?'. Together they form a unique fingerprint.