Skip to main navigation Skip to search Skip to main content

On the use of three thermocouples to verify a pcb profile during reflow

Research output: Contribution to specialist publicationArticle

Abstract

An initial study was conducted to determine if just three thermocouples could verify a printed circuit board (PCB) profile during reflow. Three of the 20 channels were used to record the temperatures on the leading edge of the PWB laminate while the other 17 were distributed around the PCB in critical and noncritical locations. Four different Pb-free reflow profiles were planned, a baseline profile and three other profiles that represent changes to the stability of the oven. The data were analyzed by looking at each individual T/C in the group, and second, by looking at the grouped behavior of the three T/Cs. A one-was Analysis of Variance (ANOVA) was conducted. The MCT was used to determine if differences in the performance of the T/Cs between the different profiles are significant. There is evidence to support that the reflow oven used in this experiment may need to be serviced soon.

Original languageEnglish
Pages33-36
Number of pages4
Volume20
No6
Specialist publicationCircuits Assembly
StatePublished - Jun 2009

Fingerprint

Dive into the research topics of 'On the use of three thermocouples to verify a pcb profile during reflow'. Together they form a unique fingerprint.

Cite this