Optimization of atrial defibrillation with a dual-coil, active pectoral lead system

  • Eric J. Rashba
  • , Stephen R. Shorofsky
  • , Robert W. Peters
  • , Michael R. Gold
  • University of Maryland, Baltimore
  • Medical University of South Carolina

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Introduction: Atrial defibrillation can be achieved with standard implantable cardioverter defibrillator (ICD) leads, but the optimal shocking configuration is unknown. The objective of this prospective study was to compare atrial defibrillation thresholds (DFTs) with three shocking configurations that are available with standard ICD leads. Methods and Results: This study was a prospective, randomized, paired comparison of shocking configurations on atrial DFTs in 58 patients. The lead system evaluated was a transvenous defibrillation lead with coils in the superior vena cava (SVC) and right ventricular apex (RV) and a left pectoral pulse generator emulator (Can). In the first 33 patients, atrial DFT was measured with the ventricular triad (RV → SVC + Can) and unipolar (RV → Can) shocking pathways. In the next 25 patients, atrial DFT was measured with the ventricular triad and the proximal triad (SVC → RV + Can) configurations. Delivered energy at DFT was significantly lower with the ventricular triad compared to the unipolar configuration (4.7 ± 3.7 J vs 10.1 ± 9.5 J, P < 0.001). Peak voltage and shock impedance also were significantly reduced (P < 0.001). There was no significant difference in DFT energy when the ventricular triad and proximal triad shocking configurations were compared (3.6 ± 3.0 J vs 3.4 ± 2.9 J for ventricular and proximal triad, respectively, P = NS). Although shock impedance was reduced by 13% with the proximal triad (P < 0.001), this effect was offset by an increased current requirement (10%). Conclusion: The ventricular triad is equivalent or superior to other possible shocking pathways for atrial defibrillation afforded by a dual-coil, active pectoral lead system. Because the ventricular triad is also the most efficacious shocking pathway for ventricular defibrillation, this pathway should be preferred for combined atrial and ventricular defibrillators.

Original languageEnglish
Pages (from-to)790-794
Number of pages5
JournalJournal of Cardiovascular Electrophysiology
Volume15
Issue number7
DOIs
StatePublished - Jul 2004

Keywords

  • Atrial fibrillation
  • Defibrillation threshold
  • Implantable cardioverter defibrillator