Skip to main navigation Skip to search Skip to main content

Permanent and atrial-synchronized ventricular stimulation for clinically stable patients with normal or impaired left ventricular systolic function

  • John A. Chiladakis
  • , Nikolaos Koutsogiannis
  • , Andreas Kalogeropoulos
  • , Fani Zagli
  • , Ilias Sihlimiris
  • , Dimitrios Alexopoulos

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Background: Ventricular desynchronization imposed by permanent dual-chamber ventricular pacing (VDD) may compromise ventricular function. Methods: We investigated the impact of background VDD pacing on the right and left ventricular (LV) function on 129 clinically stable outpatients (mean age 69 ± 10) implanted chronically with a dual-chamber pacemaker or an automatic defibrillator by using echocardiographic techniques including tissue doppler imaging (TDI) and color M-mode (CMM) examinations, and B-type natriuretic peptide (BNP) measurements. Patients were divided into two groups of normal (n = 65) or impaired (n = 64) LV systolic function (ejection fraction 63 ± 6% and 38 ± 10%, respectively) according to clinical and echocardiographic criteria. Each patient group included two subgroups on the basis of the underlying permanent and atrial-synchronized heart rhythm: either intrinsic ventricular activation (IVA) or VDD pacing. Results: The BNP levels (mean, 95% CI) of patients with impaired LV systolic function were approximately threefold higher than those of patients with normal LV systolic function [189 (145-245) pg/mL vs 65 (50-85) pg/mL, P < 0.0001], but did not differ between subgroups of patients with IVA vs VDD pacing. By two-way analysis of variance and analysis of covariance, and after adjustment for age and gender, significant VDD pacing effects were found in terms of lower E/A ratio (P < 0.05) and increased LV end-systolic volume (P < 0.05). VDD pacing did not significantly affect the BNP levels and the LV filling pressures, as determined by the E/Ea and E/Vp ratios. Conclusions: Long-term VDD pacing may not be harmful in clinically stable patients with normal or moderately reduced LV systolic function.

Original languageEnglish
Pages (from-to)182-187
Number of pages6
JournalPACE - Pacing and Clinical Electrophysiology
Volume30
Issue number2
DOIs
StatePublished - Feb 2007

Keywords

  • Permanent VDD pacing
  • Ventricular function

Fingerprint