TY - GEN
T1 - PMU placement for state estimation considering measurement redundancy and controlled islanding
AU - Akhlaghi, Shahrokh
AU - Zhou, Ning
AU - Wu, N. Eva
N1 - Publisher Copyright: © 2016 IEEE.
PY - 2016/11/10
Y1 - 2016/11/10
N2 - To select optimal locations for placing phasor measurement units (PMU), in this paper, a two-step convex optimization approach to attain the full network observability of a power system in both the normal operation conditions and controlled islanding operation conditions is proposed. The objective is to get the minimum number of PMUs which guarantees the system full observability with the maximum measurement redundancy. In the first step, a minimization model is applied to convex programing (cvx) to determine the minimum number of PMUs and all the possible candidate buses, which ensures the full network observability. In the second step, in the cases of multiple solutions, a maximization model is applied to cvx to maximize the measurement redundancy. Furthermore, the effect of zero-injection buses is considered to further reduce the number of required PMUs. The proposed approach is tested on three IEEE test systems, i.e. IEEE 14-bus, 30-bus and 118-bus, to demonstrate its effectiveness.
AB - To select optimal locations for placing phasor measurement units (PMU), in this paper, a two-step convex optimization approach to attain the full network observability of a power system in both the normal operation conditions and controlled islanding operation conditions is proposed. The objective is to get the minimum number of PMUs which guarantees the system full observability with the maximum measurement redundancy. In the first step, a minimization model is applied to convex programing (cvx) to determine the minimum number of PMUs and all the possible candidate buses, which ensures the full network observability. In the second step, in the cases of multiple solutions, a maximization model is applied to cvx to maximize the measurement redundancy. Furthermore, the effect of zero-injection buses is considered to further reduce the number of required PMUs. The proposed approach is tested on three IEEE test systems, i.e. IEEE 14-bus, 30-bus and 118-bus, to demonstrate its effectiveness.
KW - Controlled islanding
KW - Convex optimization
KW - Measurement redundancy
KW - Optimal PMU placement (OPP)
KW - Zeroinjection bus (ZIB)
UR - https://www.scopus.com/pages/publications/85002486036
U2 - 10.1109/PESGM.2016.7741546
DO - 10.1109/PESGM.2016.7741546
M3 - Conference contribution
T3 - IEEE Power and Energy Society General Meeting
BT - 2016 IEEE Power and Energy Society General Meeting, PESGM 2016
PB - IEEE Computer Society
T2 - 2016 IEEE Power and Energy Society General Meeting, PESGM 2016
Y2 - 17 July 2016 through 21 July 2016
ER -