In this study, we evaluated the ability of an observer to identify abnormal foci on CT and how that ability is affected by changing the search field size from a whole abdomen to the liver region alone. A 2-Alternatc Forced Choice (2 AFC) experimental paradigm was used to quantify observer detection performance. Each AFC experiment yielded the intensity needed to achieve 92% accuracy in lesion detection (I92%). Abdominal images were obtained at an x-ray tube voltage of 120 kV with a CTDIvol of 20 mGy. Circular lesions were generated by projecting spheres onto the image plane, followed by blurring function. Five lesion sizes (5 mm, 7 mm, 10 mm, 12 mm, and 15 mm), and four readers who were extensively trained in AFC methodology, were used in the 2AFC experiments. Each experiment was repeated 4 times to improve the experimental precision, as well as to provide an estimate of experimental uncertainty. For each observer, the experimental order of the 40 experiments was randomized to eliminate learning curve and/or observer fatigue. We measured contrast detail slopes for both Abdomen and Liver search field size, and determined ratio of I92% value for Abdomen search field to the corresponding I 92%for the Liver search field (i.e., Rabd:liv). Values of Rabd:livprovides quantitative indicator of the relative difficulty of detection lesions in the whole Abdomen relative to lesion detection restricted to the Liver. The slope of the contrast detail curve for the Abdomen search field was -0.03, whereas the corresponding slope for the Liver search field was -0.18. Rabd:livranged between 1.3 and 1.6, with an average of 1.4 ± 0.1. The value of Rabd:livmonotonically increased from 1.35 for 5 mm lesions to nearly 1.6 for the largest 15 mm lesion. The results of our study indicate that limiting the area of search to the liver on a CT of the abdomen improves the detection of mass lesions. This finding is almost certainly related to the fact that the liver provides a relatively homogenous background for identifying abnormalities, while the rest of the abdomen is much more heterogeneous. The clinical relevance of our findings is that CT can have limitations for detection of mass lesions outside of the liver, and sizes of masses necessary for detection are larger outside the liver than within.

Original languageEnglish
Title of host publicationMedical Imaging 2010
Subtitle of host publicationPhysics of Medical Imaging
EditionPART 3
DOIs
StatePublished - 2010
EventMedical Imaging 2010: Physics of Medical Imaging - San Diego, CA, United States
Duration: Feb 15 2010 → Feb 18 2010

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
NumberPART 3
Volume7622

Conference

ConferenceMedical Imaging 2010: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period02/15/10 → 02/18/10