Skip to main navigation Skip to search Skip to main content

Seismic retrofit of flexible steel frames using thin infill panels

  • Areva

Research output: Contribution to journalArticlepeer-review

54 Scopus citations

Abstract

Non-linear inelastic analyses are conducted to investigate how structural behavior is affected when thin infills of steel, low yield steel, or Shearfill fabric are used to seismically retrofit steel frames located in regions of low and high seismicity, namely New York City and Memphis. A typical three-bay frame extracted from an actual 20-story hospital building in New York City is considered for this purpose. Fully rigid and perfectly flexible frame connection rigidities are considered to capture the extremes of frame behavior. It is found that the use of even very thin steel infill panels can significantly reduce story drifts without significant increases in floor accelerations, and that low yield steel behaves slightly better than standard constructional grade steel under extreme seismic conditions but at the cost of some extra material. It is also concluded that Shearfill membranes may not have the necessary strength and stiffness to be an effective retrofit solution, unless a thick membrane having multiple layers can be constructed.

Original languageEnglish
Pages (from-to)443-453
Number of pages11
JournalEngineering Structures
Volume24
Issue number4
DOIs
StatePublished - Apr 2002

Fingerprint

Dive into the research topics of 'Seismic retrofit of flexible steel frames using thin infill panels'. Together they form a unique fingerprint.

Cite this