Skip to main navigation Skip to search Skip to main content

Study of a Passive Gating Grid for Ion Back Flow Suppression

  • Stony Brook University

Research output: Contribution to journalConference articlepeer-review

Abstract

Space Charge (SC) distortions are some of the main issues for high-resolution Time Projection Chambers (TPC). The two main SC sources are those from primary ionizations and those that result from amplification stages. The gain stages are required to increase the electron (e -) signal above electronics noise levels, but this inevitably creates extra ions. These ions can enter the drift region and distort the electric field, and thus lower the detector performance. We will present a brief motivation for our Ion Back Flow (IBF) studies along with explanations of existing techniques and our simulation results to reduce IBF. We propose several mesh structures along with static bi-polar gating. Further, we discuss position distortions in e - trajectories due to a static bi-polar grid and use these distortions to compensate for non-linear responses of our Zig-Zag pad readout.

Original languageEnglish
Article number012026
JournalJournal of Physics: Conference Series
Volume1498
Issue number1
DOIs
StatePublished - Jun 11 2020
Event6th International Conference on Micro Pattern Gaseous Detectors, MPGD 2019 - La Rochelle, France
Duration: May 5 2019May 10 2019

Fingerprint

Dive into the research topics of 'Study of a Passive Gating Grid for Ion Back Flow Suppression'. Together they form a unique fingerprint.

Cite this