TY - GEN
T1 - The effect of amorphous selenium thickness on imaging performance of contrast enhanced digital breast tomosynthesis
AU - Hu, Yue Houng
AU - Scaduto, David A.
AU - Zhao, Wei
PY - 2012
Y1 - 2012
N2 - Digital breast tomosynthesis (DBT) and contrast enhancement (CE) for both DBT (CEDBT) and planar mammography (CEDM) are being investigated to increase conspicuity of malignant lesions. To image above the k-edge of iodine (33 keV), CEDBT requires x-ray energies higher than those of typical mammograms (∼28 kVp). Increasing the thickness of the detector's amorphous selenium (a-Se) layer improves x-ray absorption and detective quantum efficiency (DQE), particularly at higher energies. For DBT, where systems are often designed with partially isocentric geometries, thicker a-Se layers may result in degradation of the modulation transfer function (MTF) for oblique views. We employed a cascaded linear system model to analyze the effect of oblique entry on MTF. Also, the model was experimentally validated using 200 and 300 μm a-Se flat panel imagers. Finally, we use an ideal-observer SNR model for projection and DBT imaging to optimize a-Se layer thickness for detectability of iodinated objects.
AB - Digital breast tomosynthesis (DBT) and contrast enhancement (CE) for both DBT (CEDBT) and planar mammography (CEDM) are being investigated to increase conspicuity of malignant lesions. To image above the k-edge of iodine (33 keV), CEDBT requires x-ray energies higher than those of typical mammograms (∼28 kVp). Increasing the thickness of the detector's amorphous selenium (a-Se) layer improves x-ray absorption and detective quantum efficiency (DQE), particularly at higher energies. For DBT, where systems are often designed with partially isocentric geometries, thicker a-Se layers may result in degradation of the modulation transfer function (MTF) for oblique views. We employed a cascaded linear system model to analyze the effect of oblique entry on MTF. Also, the model was experimentally validated using 200 and 300 μm a-Se flat panel imagers. Finally, we use an ideal-observer SNR model for projection and DBT imaging to optimize a-Se layer thickness for detectability of iodinated objects.
KW - MTF
KW - amorphous selenium
KW - cascaded linear system model
KW - contrast enhancement
KW - digital breast tomosynthesis
KW - ideal observer signal to noise ratio
UR - https://www.scopus.com/pages/publications/84864860083
U2 - 10.1007/978-3-642-31271-7_2
DO - 10.1007/978-3-642-31271-7_2
M3 - Conference contribution
SN - 9783642312700
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 9
EP - 16
BT - Breast Imaging - 11th International Workshop, IWDM 2012, Proceedings
T2 - 11th International Workshop on Breast Imaging, IWDM 2012
Y2 - 8 July 2012 through 11 July 2012
ER -