TY - GEN
T1 - Ultra-Efficient and Sustainable Hybrid Cooling System for High-Performance Computing Using Green Refrigerants
AU - Heydari, Ali
AU - Manaserh, Yaman
AU - Shahi, Pardeep
AU - Chowdhury, Uschas
AU - Busch, Greg
AU - Kundu, Arpan
AU - Al-Zu’bi, Omar
AU - Mehrabi, Mehdi
AU - Rodriguez, Jeremy
AU - Sammakia, Bahgat
AU - Ortega, Alfonso
N1 - Publisher Copyright: © 2026 ASHRAE.
PY - 2026
Y1 - 2026
N2 - Data centers, which consume a significant share of the total U.S. electricity supply and continue to grow rapidly, urgently require more energy-efficient strategies.. With cooling infrastructure responsible for up to 40% of this demand, thermal management has emerged as a critical area for improvement. Addressing this need, our previous ASHRAE work introduced a Hybrid direct-to-chip Pumped Two-Phase and Single-Phase Immersion Cooling System that eliminated reliance on energy- intensive air cooling, enabled operation without chillers in extreme climates, and significantly reduced environmental impact through the use of eco-friendly refrigerants with GWP < 10. In this continuation, we present a new Immersive Tray technology designed to support next-generation racks exceeding 1 MW. The rack is deployed inside a shipping container with an integrated, compact heat-rejection system, enabling a self-contained and transportable high-density solution. The Immersive Tray advances the hybrid cooling architecture by reducing system complexity and cost, and minimizing immersion fluid requirements. This advancement is achieved through the use of refrigerants that absorb heat directly from the immersion fluid while ensuring that the immersion medium remains fully contained within the server. This work extends the investigation through a comprehensive CFD study and a detailed PUE analysis, providing deeper insights into system performance, scalability, and energy-efficiency potential. The integration of the new Immersive Tray technology with the Two-phase cold plate subsystem demonstrated that the enhanced design can achieve ultra-low PUE values—approaching 1.03—while simultaneously improving scalability, reducing system weight, and minimizing environmental impact. These findings highlight the pivotal role of refrigerants in enabling hybrid cooling to emerge as a sustainable, high-performance solution for future containerized data centers.
AB - Data centers, which consume a significant share of the total U.S. electricity supply and continue to grow rapidly, urgently require more energy-efficient strategies.. With cooling infrastructure responsible for up to 40% of this demand, thermal management has emerged as a critical area for improvement. Addressing this need, our previous ASHRAE work introduced a Hybrid direct-to-chip Pumped Two-Phase and Single-Phase Immersion Cooling System that eliminated reliance on energy- intensive air cooling, enabled operation without chillers in extreme climates, and significantly reduced environmental impact through the use of eco-friendly refrigerants with GWP < 10. In this continuation, we present a new Immersive Tray technology designed to support next-generation racks exceeding 1 MW. The rack is deployed inside a shipping container with an integrated, compact heat-rejection system, enabling a self-contained and transportable high-density solution. The Immersive Tray advances the hybrid cooling architecture by reducing system complexity and cost, and minimizing immersion fluid requirements. This advancement is achieved through the use of refrigerants that absorb heat directly from the immersion fluid while ensuring that the immersion medium remains fully contained within the server. This work extends the investigation through a comprehensive CFD study and a detailed PUE analysis, providing deeper insights into system performance, scalability, and energy-efficiency potential. The integration of the new Immersive Tray technology with the Two-phase cold plate subsystem demonstrated that the enhanced design can achieve ultra-low PUE values—approaching 1.03—while simultaneously improving scalability, reducing system weight, and minimizing environmental impact. These findings highlight the pivotal role of refrigerants in enabling hybrid cooling to emerge as a sustainable, high-performance solution for future containerized data centers.
UR - https://www.scopus.com/pages/publications/105038358914
U2 - 10.63044/w26man70
DO - 10.63044/w26man70
M3 - Conference contribution
SN - 9781964173566
T3 - ASHRAE Transactions
SP - 533
EP - 540
BT - ASHRAE Transactions
PB - American Society of Heating Refrigerating and Air-Conditioning Engineers
T2 - ASHRAE Winter Conference, 2026
Y2 - 31 January 2026 through 4 February 2026
ER -