Skip to main navigation Skip to search Skip to main content

Ultrasound and fluoroscopy are unnecessary for injections into the arthritic hip

  • Tom Schmidt-Braekling
  • , Wenzel Waldstein
  • , Lisa Renner
  • , Alejandro Gonzales Della Valle
  • , Jad Bou Monsef
  • , Friedrich Boettner
  • Hospital for Special Surgery - New York

Research output: Contribution to journalArticlepeer-review

8 Scopus citations

Abstract

Purpose: We investigated the effectiveness of non-image-guided hip injections. Methods: We retrospectively evaluated 369 intra-articular hip injections in 331 patients using anatomical landmarks. The percentage and duration of pain relief was documented. Hip injections were grouped in responders and nonresponders (50 % maximum pain relief as a cut off). Results: In 82% (n = 304) of hip injections, patients responded positively and experienced >50 % pain relief. Nonresponders had a significantly higher body mass index (p = 0.007). Conclusions: Hip injections using anatomical landmarks are an effective treatment option for patients with osteoarthritis of the hip.

Original languageEnglish
Pages (from-to)1495-1497
Number of pages3
JournalInternational Orthopaedics
Volume39
Issue number8
DOIs
StatePublished - Aug 27 2015

Keywords

  • Anatomical landmarks
  • Hip injection
  • Non-image-guided
  • Osteoarthritis

Fingerprint