Skip to main navigation Skip to search Skip to main content

Utilization and Cancer Yield of Probably Benign Assessment Category in the National Mammography Database: 2009 to 2018

  • Mai A. Elezaby
  • , Lu Mao
  • , Elizabeth S. Burnside
  • , Margarita L. Zuley
  • , Wendie A. Berg
  • , Mythreyi Bhargavan-Chatfield
  • , Cindy S. Lee
  • University of Wisconsin-Madison
  • University of Pittsburgh
  • American College of Radiology

Research output: Contribution to journalArticlepeer-review

1 Scopus citations

Abstract

Purpose: Data on utilization rate and cancer yield of BI-RADS® category 3 in routine clinical practice in diagnostic mammography are sparse. The aim of this study was to determine utilization rate and cancer yield of BI-RADS 3 in diagnostic mammography in the ACR National Mammography Database (NMD). Methods: Retrospective analysis of NMD mammograms from January 1, 2009, to June 30, 2018, was performed. BI-RADS 3 utilization rate in diagnostic setting was calculated and stratified by patient, facility, and examination-level variables. Patient-level cancer yield was calculated among women with BI-RADS 3 assessment and adequate follow-up (imaging follow-up ≥24 months or biopsy). Logistic regression was performed to assess the odds of utilization of BI-RADS 3, with respect to facility, examination, and patient variables, and the odds of malignancy among patients with probably benign findings. Chi-square and t tests were used to determine significance (P < .05). Results: Data from 19,443,866 mammograms from 500 NMD facilities across 31 states were analyzed, of which 3,039,952 were diagnostic mammograms. Utilization rate of BI-RADS 3 was 15.5% (470,155 of 3,039,952) in the diagnostic setting. There was a statistically significant difference in BI-RADS 3 utilization rate across all collected variables (P < .001). Patient-level cancer yield at 2-year follow-up was 0.91% (2,009 of 220,672; 95% confidence interval [CI], 0.87%-0.95%) in the diagnostic setting. Patient and examination variables associated with significantly higher likelihood of malignancy included calcifications (odds ratio, 4.27; 95% CI, 2.43-7.51), patient age > 70 years (odds ratio, 3.77; 95% CI, 2.49-5.7), and presence of prior comparisons (odds ratio, 1.23; 95% CI, 1.07-1.42). Conclusions: In the NMD, BI-RADS 3 assessment was common in diagnostic mammography (15.5%), with an overall cancer yield of 0.91%, less than the benchmark of 2%. Utilization trends in diagnostic mammography warrant further research for optimization of use.

Original languageEnglish
Pages (from-to)604-614
Number of pages11
JournalJournal of the American College of Radiology
Volume19
Issue number5
DOIs
StatePublished - May 2022

Keywords

  • Probably benign
  • cancer yield
  • diagnostic mammography
  • utilization rate

Fingerprint

Dive into the research topics of 'Utilization and Cancer Yield of Probably Benign Assessment Category in the National Mammography Database: 2009 to 2018'. Together they form a unique fingerprint.

Cite this