TY - GEN
T1 - Window operation and its impacts on thermal comfort and energy use
AU - Wang, Liping
PY - 2014
Y1 - 2014
N2 - Operable windows provide occupants' ability to control over local environment and satisfy human's expectation to access to outdoor environment. Operation strategies for operable windows can have significant impacts on indoor thermal comfort and energy consumption of building performance. It is not uncommon that building facility managers complain that operable windows were left open in buildings with a conventional HVAC system. However, optimum control strategies of window operation can improve thermal comfort and reduce energy consumption for building using natural ventilation or mixed mode ventilation. The study focuses on the investigation of the impacts of window operations on building performance for different types of building systems including natural ventilation, mixed mode ventilation, and conventional HVAC systems in a medium-size reference office building. Building performance simulation tool̄EnergyPlus is used to simulate window operations for each system in three different climates. Various control strategies of window operations for building operation systems, implemented using (EMS) in EnergyPlus, are evaluated based on the criteria of thermal comfort and energy consumption. The results highlight the impacts of window operations on thermal comfort and energy use and identify that hybrid ventilation for perimeter zones has 12-20 % saving potentials of annual HVAC site energy consumption.
AB - Operable windows provide occupants' ability to control over local environment and satisfy human's expectation to access to outdoor environment. Operation strategies for operable windows can have significant impacts on indoor thermal comfort and energy consumption of building performance. It is not uncommon that building facility managers complain that operable windows were left open in buildings with a conventional HVAC system. However, optimum control strategies of window operation can improve thermal comfort and reduce energy consumption for building using natural ventilation or mixed mode ventilation. The study focuses on the investigation of the impacts of window operations on building performance for different types of building systems including natural ventilation, mixed mode ventilation, and conventional HVAC systems in a medium-size reference office building. Building performance simulation tool̄EnergyPlus is used to simulate window operations for each system in three different climates. Various control strategies of window operations for building operation systems, implemented using (EMS) in EnergyPlus, are evaluated based on the criteria of thermal comfort and energy consumption. The results highlight the impacts of window operations on thermal comfort and energy use and identify that hybrid ventilation for perimeter zones has 12-20 % saving potentials of annual HVAC site energy consumption.
KW - Energy
KW - Mixed mode
KW - Natural ventilation
KW - Thermal comfort
KW - Window operation
UR - https://www.scopus.com/pages/publications/84894136283
U2 - 10.1007/978-3-642-39581-9_26
DO - 10.1007/978-3-642-39581-9_26
M3 - Conference contribution
SN - 9783642395802
T3 - Lecture Notes in Electrical Engineering
SP - 259
EP - 266
BT - Proceedings of the 8th International Symposium on Heating, Ventilation and Air Conditioning
T2 - 8th International Symposium on Heating, Ventilation, and Air Conditioning, ISHVAC 2013
Y2 - 19 October 2013 through 21 October 2013
ER -